Environmental Testing Services: Ensuring Product Reliability and Durability
Environmental testing is a critical aspect of product development and quality assurance, ensuring that products can withstand the rigors of various environmental conditions they may encounter during their lifecycle. At ATCC Lab, we offer comprehensive environmental testing services to assess the performance, reliability, and durability of products across a wide range of environmental factors. From altitude and temperature changes to dust and vibration, our testing capabilities cover all aspects of environmental resilience.
Altitude Test:
The altitude test evaluates the performance of products at different altitudes, simulating conditions encountered at varying elevations. This test assesses the effects of low atmospheric pressure on product functionality and safety, ensuring that products perform reliably at high altitudes.
Bump Test:
The bump test simulates mechanical shocks and impacts that products may experience during transportation, handling, or use. By subjecting products to controlled impacts, this test assesses their resistance to physical shock and verifies their structural integrity and durability.
Change in Temperature Test:
This test evaluates the performance of products under extreme temperature variations, including rapid temperature changes. It assesses the effects of thermal expansion and contraction on product materials and components, ensuring reliable operation in diverse temperature environments.
Cold Test:
The cold test exposes products to extremely low temperatures, simulating cold climate conditions. It assesses the impact of low temperatures on product performance, functionality, and materials, ensuring that products can withstand freezing temperatures without degradation.
Colour Chromaticity:
Colour chromaticity testing evaluates the colour consistency and accuracy of products under different lighting conditions. It ensures that products maintain consistent colour appearance and meet specified colour standards, enhancing their aesthetic appeal and usability.
Damp Heat Test:
The damp heat test assesses product performance under high humidity and temperature conditions, simulating humid and tropical climates. It evaluates the effects of moisture and heat on product materials, components, and electronics, ensuring resistance to corrosion, mold, and electrical failures.
Drop Test:
The drop test evaluates the impact resistance of products by subjecting them to controlled free-fall drops. It assesses the ability of products to withstand accidental drops and impacts, verifying their ruggedness and durability in real-world scenarios.
Dry Heat Test:
The dry heat test exposes products to high temperatures in a dry environment, simulating hot and arid climate conditions. It assesses the effects of heat on product materials, components, and performance, ensuring reliability and functionality under extreme heat.
Dust Test:
The dust test evaluates the ingress protection of products against dust and particulate matter. It assesses the ability of products to prevent dust ingress and maintain operational integrity in dusty environments, ensuring reliability and longevity.
Energy Efficient LED based Luminaire Units For Passenger Coaches (All Tests):
Our testing services cover all aspects of environmental testing for LED-based luminaire units used in passenger coaches. From thermal performance and vibration resistance to moisture resistance and electrical safety, we ensure that LED luminaires meet stringent performance and reliability requirements for railway applications.
Glow Wire Test:
The glow wire test evaluates the fire resistance of products by subjecting them to a hot wire ignition source. It assesses the ability of products to withstand ignition from glowing elements and prevent fire propagation, ensuring safety and compliance with fire safety standards.
High Temperature Humidity:
This test combines high temperature and humidity conditions to simulate hot and humid climate environments. It assesses the effects of heat and moisture on product materials, components, and performance, ensuring resistance to corrosion, mold, and electrical failures.
IK Test / Impact Test:
The IK test, also known as the impact test, evaluates the mechanical impact resistance of products. It assesses the ability of products to withstand impact forces and protect against damage, ensuring ruggedness and durability in harsh operating conditions.
IP Test (Ingress Protection Test):
The IP test, also known as the ingress protection test, assesses the degree of protection provided by products against solid particles and liquids. It assigns an IP rating based on the level of protection against ingress, ensuring that products meet specified environmental protection requirements.
Low Temperature:
The low-temperature test exposes products to extremely cold temperatures, simulating cold climate conditions. It assesses the effects of low temperatures on product performance, functionality, and materials, ensuring reliable operation in freezing conditions.
Needle Flame Test:
The needle flame test evaluates the fire resistance of products by subjecting them to a controlled flame ignition source. It assesses the ability of products to withstand ignition from small flames and prevent fire propagation, ensuring compliance with fire safety standards.
Photometric Test:
The photometric test evaluates the light output, distribution, and quality of lighting products. It measures parameters such as luminous flux, luminous intensity, and colour rendering, ensuring that products meet specified photometric performance requirements.
Rain Test:
The rain test assesses the water resistance of products by subjecting them to simulated rainfall. It evaluates the ability of products to prevent water ingress and maintain operational integrity in wet environments, ensuring reliability and durability.
Salt Fog Test:
The salt fog test evaluates the corrosion resistance of products by exposing them to a salt-laden fog environment. It assesses the ability of products to withstand salt corrosion and maintain operational integrity in marine and coastal environments.
Salt Spray Test:
Similar to the salt fog test, the salt spray test evaluates the corrosion resistance of products by subjecting them to a salt spray environment. It assesses the ability of products to withstand salt corrosion and maintain operational integrity in harsh outdoor environments.
Shock Test:
The shock test evaluates the mechanical shock resistance of products by subjecting them to controlled shock impulses. It assesses the ability of products to withstand mechanical shocks and vibrations during transportation, handling, or use.
Temperature Shock:
The temperature shock test evaluates the performance of products under rapid temperature changes. It subjects products to alternating hot and cold temperature cycles, assessing their ability to withstand thermal stress and prevent damage or failure.
Topple Test:
The topple test evaluates the stability of products by subjecting them to tilting or tipping forces. It assesses the ability of products to remain stable and upright under various conditions, ensuring safety and preventing accidental tipping or falls.
Tracking Index:
The tracking index test evaluates the electrical tracking resistance of insulating materials. It assesses the resistance of materials to surface tracking and erosion when exposed to electrical stress, ensuring safety and reliability in electrical applications.
Vibration:
The vibration test evaluates the mechanical vibration resistance of products. It subjects products to controlled vibration frequencies and amplitudes, assessing their ability to withstand vibrations during transportation, operation, or use.
Vical Softening:
The Vical softening test
ENVIRONMENTAL TESTING | SPECIFICATIONS |
Altitude Test | MIL-STD-810G Method 500.5 JSS 55555 Test No. 3 MIL-STD-810F Method 500.4 ISO 15003 |
Bump Test | IEC 60068-2-27 JSS 55555, Test No. 5 JSS 50101 QM 333 Test no.13 IS 9000 (Part-7: Sec 2) |
Change in Temperature Test | ISO 16750-4 IEC 60068-2-14 IS 9000 (Part 14/Sec 1 to 3) JSS 55555, Test No. 22 JSS 50101 QM 333, Test no.4 |
Cold Test | IEC 60068-2-1 IS 9000 (Part 2/Sec 1 to 4) QM 333, Test no.1 IEC 60571 Cl. 12.2.4 JSS 55555 Test No. 20 MIL-STD-810G Method 502.5 |
Colour Chromaticity | ICAO Annex 14 Volume I, (Cl. 5.3.5.31) |
Damp Heat Test | JSS 55555, Test No. 10 QM 333, Test no.5 IEC 60068-2-78 IS 9000 (Part 4) IEC 60571 Cl. 12.2.6 ISO 16750-4 IEC 60068-2-3 IS 9000 (Part 5/Sec 1 to 2): IEC 60068-2-30 JSS 55555, Test No. 10 JSS 50101 QM 333 Test no.3 |
Drop Test | MIL-STD-810F ASTM D5279 IEC 60068-2-32 IEC 60068-2-31 ISO 16750-4 JSS 55555 MIL-STD-810G |
Dry Heat Test | IEC 60068-2-2 IS 9000 (Part 3/Sec 1 to 5) JSS 55555 Test No. 17 JSS 50101 QM 333, Test no.2 ISO 16750-4 IEC 60571 Cl. 12.2.5 MIL-STD-810G Method 501.5 |
Dust Test | IEC 60529 IS 9000 (Part12) JSS 55555 Test No. 14 JSS 50101 |
Energy Efficient LED based Luminaire Units For Passenger Coaches (All Tests) | RDSO/PE/SPEC/TL/0091, (Cl. 8), (xvii) |
Glow Wire Test | IS 11000 (Part 2/Sec 1): 2018 IEC 60695-2-10: 2013 |
High Temperature | MIL-STD-810F, Method 501.4 |
Humidity | MIL-STD-810F, Method 507.4 |
IK Test / Impact Test (IK Code 01, 02, 03, 04, 05, 06, 07, 08, 09 & 10) | IEC 62262 IEC 60068-2-75 |
IP Test (/ Ingress Protection Test / Degree of Protection Test) IP Code (First numeric) 1X, 2X, 3X, 4X, 5X, 6X and (Second Numeric)1X, 2X, 3X, 4X, 5X, 6X, 7X, 8X | IS 60529 IEC 60529 IS/IEC 60034 : Part 5 |
Low Temperature | MIL-STD-810F, Method 502.4 |
Needle Flame Test | IS 11000 (Part 2/Sec 2): 2008 IEC 60695-11-5: 2016 |
Photometric test | ICAO Annex 14 Volume I, (Cl. 5.3.5.32) |
Rain Test | MIL-STD-810F, Method 506.4 |
Salt Fog Test | MIL-STD-810F,Method 509.4 |
Salt Spray Test | ISO 16750-4 Cl. 5.5 JSS 55555 Test No. 7-9 QM 333 Test No. 9 |
Shock Test | MIL-STD-810F , Method 516.5 IEC 60068-2-27 IS 9000 (Part-7/Sec-1) JSS 55555 Test No. 24 |
Temperature Shock | MIL-STD-810F , Method 503.4 |
Topple Test | QM 333 Test No. 11 JSS 55555 Test No.26 |
Tracking Index | IS 2824 |
Vibration | IEC 60068-2-6 MIL-STD-810F, Method 514.5 IEC 60068-2-64 JSS 55555 Test No. 28 JSS 50101 QM 333 Test No. 6 IEC 61373 IEC 60068-2-6 IS 9000 (Part 8) JSS 55555 JSS 50101 QM 333 Test No. 6 |
Vical Softening | ISO 306 |